Ball Valves
Standard Ball Vavles
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• Bi-directional flow
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
Standard Ball Valve With Access Port
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• Bi-directional flow
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
IBV Series
• Design Pressure (DP) / Maximum abnormal pressure (MAP): 775 psig, 53 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM™ Seal Technology
Transcritical
• Design Pressure (DP) / Maximum abnormal pressure (MAP): 2031 psi, 140 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Designed for transcritical CO2 systems
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM Seal Technology
Subcritical
• Design Pressure (DP) / Maximum abnormal pressure (MAP): 60 bar
• Continuous operating temperature (COT): ‐40°F/300°F, ‐40°C/149°C
• Bi-directional flow
• Brass body with copper-iron alloy connections
• Full port construction to match line size
• Specially selected o-ring material compatible for CO2 operating conditions
FTG X FTG
• Design Pressure (DP) / Maximum abnormal pressure (MAP): 775 psig, 53 bar
• Continuous operating temperature (COT): ‐40°F/300°F, ‐40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture‐proof encapsulated stem
• MCM Seal Technology
Multi Split Flare x ODS
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature: -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
Multi-Split Flare X ODS
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature: -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
Multi-Split Male X Female Flare
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
Multi-Split ODS X ODS
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
3-Way
• Design Pressure (DP) / Maximum abnormal pressure (MAP): 700 psig, 48 bar
• Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
• Full port construction to match line size ID
• Internally equalized ball design
• Rupture-proof encapsulated stem
• MCM™ Seal Technology
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU
Actuated
• Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
• Power Supply: 24 VAC
• Actuator Ambient Temperature: -22°F to 130°F, -30°C to 54°C
• Valve Refrigerant Temperature: -40°F to 300°F, -40°C to 149°C
• Full shutoff capability
• Gradual Open/close stops line hammer
• Remote operating capability
• Removable actuator for quick change replacement
• Manual override and valve positioning
• Electronic overload protection
• UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU